Inclination measurement device for hospital beds’ in ICU

Medidor de inclinación de camas hospitalarias en UCI

Autores/as

Palabras clave:

Inertial measurement unit, Mechanical ventilation, Tilt angle, Ventilator-associated pneumonia, Wi-Fi communication (en).

Palabras clave:

Unidad de medición inercial, Ventilación mecánica, Ángulo de inclinación, Neumonía asociada al ventilador, Comunicación Wi-Fi (es).

Resumen (en)

Ventilator-associated pneumonia is acquired by many patients connected to an artificial airway, causing their death of a great percentage to those who are affected. A close relationship has been found between ventilator-associated pneumonia and hospital beds tilting angle which the patients rest on. The correct position has been established between 30° and 45° to reduce the likelihood of ventilator-associated pneumonia; so a tilt sensor linked to the hospital beds is a good method for measuring. The present article describes an electronic device which was developed able to create a link between an IMU sensor connected to a microcontroller and a Wi-Fi module that allows to display, in a real time graphical interface, located in the control center, the current position of hospital’s beds for being monitored by the nursing staff providing a record of the patients’ status in intensive care and emergency units. Device’s performance was checked by hysteresis and fixed position test along a previously defined time where errors in measurement of inclination remain within a suitable range.

Resumen (es)

La neumonía asociada a la ventilación mecánica es una patología con una elevada tasa de mortalidad adquirida por pacientes conectados a una vía aérea artificial. Reportes bibliográficos indican una estrecha relación entre esta patología y el ángulo de inclinación de las camillas en las que reposan los pacientes –cuya posición adecuada se encuentra establecida entre 30° y 45°–; por lo que un sensor de inclinación adherido a las camillas es un adecuado método de medición. El presente artículo describe el desarrollo de un dispositivo que vincula un sensor IMU conectado a un microcontrolador con un módulo Wi-Fi, el cual provee un reporte hacia un computador del centro de control –vigilado por el personal de enfermería– a través de una interfaz gráfica que, en tiempo real, informa la posición de las camillas. Este dispositivo permite registrar la inclinación de camas en la unidad de cuidados intensivos y urgencias. El dispositivo fue sometido a pruebas de histéresis y de posición fija las cuales arrojan errores en la medición de los ángulos dentro de rangos seguros y no interfieren con el correcto funcionamiento del dispositivo.

Referencias

F. Arancibia, “Neumonía asociada a ventilación mecánica: Enfoque actual”, 2004. [Online]. Available at: https://www.medicina-intensiva.cl/revistaweb/revistas/indice/2004-2/4.pdf

E. Carrera, Y. Torreblanca, T. Gerones, L. Govantes and A. Martínez, “Acciones de enfermería en la prevención de la neumonía asociada a la ventilación mecánica. Sistema integrado de urgencias médicas”, Revista Cubana de Medicina Intensiva y Emergencias, vol. 16, no. 2, 2017.

H. Gadani, A. Vyas, and A. Kumar Kar, “A study of ventilator-associated pneumonia: Incidence, outcome, risk factors and measures to be taken for prevention”, Indian J Anaesth, vol. 54, no. 6, 2010, pp. 535-540. https://doi.org/10.4103/0019-5049.72643

J. Labarca, “Neumonía asociada a ventilación mecánica”, Revista chilena de infectología, vol. 18, no. 2, 2001. https://doi.org/10.4067/S0716-10182001018200001

E. Montial, N. Ruiz, E. Prieto, “¿Intuición o Exactitud? Posicionamiento Intuitivo de la Cabecera de la Cama en Pacientes Crítico ¿Necesitamos Medirlo?”, Enfermería intensiva, vol. 16, no. 2, 2005, pp. 51-96.

M. del Cotillo, J. Valls Matarín, “Análisis del cumplimiento de 2 medidas para prevenir la neumonía asociada a la ventilación mecánica”, Enfermería intensiva, vol. 25, no. 4, 2014, pp. 123-172.

R. Martínez and M. Romero, “Uso de Sensores Inerciales en la Medición y Evaluación de Movimiento Humano para Aplicaciones en la Salud”, Universidad Autónoma del Estado de México, México DF, 2013.

E. Van der Kruk, A. Schwab, F. Van Der Helm and D. Veeger, “Getting the Angles Straight in Speed Skating: A Validation Study on an IMU Filter Design to Measure the Lean Angle of the Skate on the Straights”, Conference: ISEA 2016, 2016.

S. Amidedin, M. Bigdeli and S. Majid, “A Feasibility Study on Application of Positioning Sensors to Online Detect of the Transformer Winding Axial Displacement”, IEEE Symposium on Industrial Electronics & Applications, 2013, pp. 1-2.

Prakhar Srivastava, M. Bajaj and A. Singh, “IOT Based Controlling of Hybrid Energy System using ESP8266”, IEEMA Engineer Infinite Conference (eTechNxT), 2018, pp. 2-3.

Espressif Systems IOT Team, “ESP8266 AT Instruction Set Version 1.5”, 2016. [Online]. Available at: https://www.espressif.com/sites/default/files/documentation/4a-esp8266_at_instruction_set_en.pdf

Cómo citar

APA

Naranjo López, D., González Jiménez, M. A., Buitrago Toro, S., y Gallego Londoño, J. (2019). Inclination measurement device for hospital beds’ in ICU. Visión electrónica, 13(1), 92–100. https://doi.org/10.14483/22484728.14408

ACM

[1]
Naranjo López, D. et al. 2019. Inclination measurement device for hospital beds’ in ICU. Visión electrónica. 13, 1 (ene. 2019), 92–100. DOI:https://doi.org/10.14483/22484728.14408.

ACS

(1)
Naranjo López, D.; González Jiménez, M. A.; Buitrago Toro, S.; Gallego Londoño, J. Inclination measurement device for hospital beds’ in ICU. Vis. Electron. 2019, 13, 92-100.

ABNT

NARANJO LÓPEZ, Daniela; GONZÁLEZ JIMÉNEZ, María Alejandra; BUITRAGO TORO, Sebastián; GALLEGO LONDOÑO, Jonathan. Inclination measurement device for hospital beds’ in ICU. Visión electrónica, [S. l.], v. 13, n. 1, p. 92–100, 2019. DOI: 10.14483/22484728.14408. Disponível em: https://revistas.udistrital.edu.co/index.php/visele/article/view/14408. Acesso em: 28 mar. 2024.

Chicago

Naranjo López, Daniela, María Alejandra González Jiménez, Sebastián Buitrago Toro, y Jonathan Gallego Londoño. 2019. «Inclination measurement device for hospital beds’ in ICU». Visión electrónica 13 (1):92-100. https://doi.org/10.14483/22484728.14408.

Harvard

Naranjo López, D. (2019) «Inclination measurement device for hospital beds’ in ICU», Visión electrónica, 13(1), pp. 92–100. doi: 10.14483/22484728.14408.

IEEE

[1]
D. Naranjo López, M. A. González Jiménez, S. Buitrago Toro, y J. Gallego Londoño, «Inclination measurement device for hospital beds’ in ICU», Vis. Electron., vol. 13, n.º 1, pp. 92–100, ene. 2019.

MLA

Naranjo López, Daniela, et al. «Inclination measurement device for hospital beds’ in ICU». Visión electrónica, vol. 13, n.º 1, enero de 2019, pp. 92-100, doi:10.14483/22484728.14408.

Turabian

Naranjo López, Daniela, María Alejandra González Jiménez, Sebastián Buitrago Toro, y Jonathan Gallego Londoño. «Inclination measurement device for hospital beds’ in ICU». Visión electrónica 13, no. 1 (enero 31, 2019): 92–100. Accedido marzo 28, 2024. https://revistas.udistrital.edu.co/index.php/visele/article/view/14408.

Vancouver

1.
Naranjo López D, González Jiménez MA, Buitrago Toro S, Gallego Londoño J. Inclination measurement device for hospital beds’ in ICU. Vis. Electron. [Internet]. 31 de enero de 2019 [citado 28 de marzo de 2024];13(1):92-100. Disponible en: https://revistas.udistrital.edu.co/index.php/visele/article/view/14408

Descargar cita

Visitas

599

Dimensions


PlumX


Descargas

Los datos de descargas todavía no están disponibles.

Artículos más leídos del mismo autor/a

Loading...