InvestigaciónCO2 monitor for measurement of ventilation in closed environments, COVID-19 prevention, and improvement of work performance
Monitor de CO2 para medida de la ventilación en ambientes cerrados, prevención del COVID-19 y mejora del rendimiento laboral
Palabras clave:
gas sensors, environmental monitoring, COVID-19, data processing, carbon dioxide (en).Palabras clave:
sensores de gas, monitoreo ambiental, COVID-19, procesamiento de datos, dióxido de carbono (es).Descargas
Resumen (en)
Objective: Humans produce and exhale CO2, thus the concentration of this gas increases in closed environments. The CO2 concentration of air is often used as a reference to measure the ventilation rate. The typical outdoor CO2 concentration is approximately 400 ppm, although it can be as high as 500 ppm. Concentrations greater than 20000 ppm result in deep breathing, higher than 100000 ppm cause visual disturbances and tremors with possible loss of consciousness and over 250000 ppm may cause death. In buildings with no change on their ventilation rate, high CO2 concentrations have negative effects on decision making and working performance. At 1000 ppm, performance is significantly reduced in six of nine decision-making metrics compared to 600 ppm. In this work, a CO2 flexible monitor is designed to measure ventilation in closed environments.
Methodology: Electrolytic and infrared CO2 sensors with a detection range of 350 to up to 10000 ppm were used. The used sensors have good sensitivity and selectivity to CO2. The gas monitor has a simple calibration system, whereby softwareautomatically adjusts the calibration curve parameters after circulating clean air. The design of a gas bench used to verify sensor calibration is also shown.
Results: A set of measurements were performed with electrochemical gas sensors and infrared (IR) gas sensors to test the functionality of the equipment. Experimental work has shown sensors have a satisfactory response for this application. The margins of error are +5 % of the reading value.
Conclusions: A low cost, flexible gas monitor for indoor environments like schools, offices, laboratories, and industries was designed in this work. Due to the flexible design, a network of gas monitors strategically distributed in the different spaces of the buildings is proposed.
Fundings: Universidad Tecnológica Nacional. Comisión Nacional de Energía Atómica. Buenos Aires, Argentina
Resumen (es)
Objetivo: Los humanos producimos y exhalamos CO2, por lo que la concentración de este gas aumenta en ambientes cerrados. La concentración de gas CO2 en el aire se utiliza a menudo como referencia para medir la tasa de ventilación. La concentración típica de CO2 al aire libre es de aproximadamente 400 ppm, aunque puede llegar a 500 ppm. Las concentraciones superiores a 20000 ppm dan como resultado una respiración profunda, superiores a 100000 ppm provocan alteraciones visuales y temblores con posible pérdida del conocimiento y superiores a 250000 ppm pueden provocar la muerte. En edificios sin cambios en su tasa de ventilación, las altas concentraciones de CO2 tienen efectos negativos en la toma de decisiones y el rendimiento laboral. A 1000 ppm, el rendimiento se reduce significativamente en seis de las nueve métricas de toma de decisiones en comparación con 600 ppm. En este trabajo se diseña un monitor flexible de CO2 para medir la ventilación en ambientes cerrados.
Metodología: Se utilizaron sensores de CO2 electrolíticos y sensores infrarrojos con un rango de detección de 350 hasta 10000 ppm. Los sensores utilizados tienen buena sensibilidad y selectividad al CO2. El monitor de gas tiene un sistema de calibración simple, mediante el cual el software ajusta automáticamente los parámetros de la curva de calibración después de hacer circular aire limpio. También se muestra el diseño de un banco de gases utilizado para verificar la calibración del sensor.
Resultados: Se realizaron un conjunto de mediciones, con sensores de gases electrolíticos químicos y sensores de gases infrarrojos (IR) probando la funcionalidad del equipo. El trabajo experimental ha demostrado que los sensores tienen una respuesta satisfactoria para esta aplicación. Los márgenes de error son 5 % del valor de lectura.
Conclusiones: En este trabajo se diseñó un monitor de gas flexible y de bajo costo para ambientes interiores como escuelas, oficinas, laboratorios e industrias. Debido al diseño flexible, se propone una red de monitores de gas distribuidos estratégicamente en los distintos espacios de los edificios.
Financiamiento: Universidad Tecnológica Nacional. Comisión Nacional de Energía Atómica. Buenos Aires, Argentina.
Referencias
Acosta Pérez, M. A., Suárez Castrillón, S. A., & Suárez Castrillón, A. M. (2016). Desarrollo y ensayo de un sensor químico de fibra óptica para la medición de concentraciones de dióxido de carbono. Revista Tecnura, 20(50). https://revistas.udistrital.edu.co/index.php/Tecnura/article/view/11558/12386
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016). Associations of cognitive function scores with carbon dioxide, ventilation, and volatile organic compound exposures in office workers: A controlled exposure study of green and conventional office environments. Environmental Health Perspectives, 124(6). https://doi.org/10.1289/ehp.1510037
Chen, C. Y., Chen, P. H., Chen, J. K., & Su, T. C. (2021). Recommendations for ventilation of indoor spaces to reduce COVID-19 transmission. In Journal of the Formosan Medical Association (Vol. 20, Issue 12). https://doi.org/10.1016/j.jfma.2021.08.007
Di Gilio, A., Palmisani, J., Pulimeno, M., Cerino, F., Cacace, M., Miani, A., & de Gennaro, G. (2021). CO2 concentration monitoring inside educational buildings as a strategic tool to reduce the risk of Sars-CoV-2 airborne transmission. Environmental Research, 202. https://doi.org/10.1016/j.envres.2021.111560
Díaz, C. M. M. (2021). Gestión ambiental: In Lecturas medio ambiente t. VIII. https://doi.org/10.2307/j.ctv25tnwb0.12
Freire-Vinueza, C., Meneses, K., & Cuesta, G. (2021). América Latina: ¿Un paraíso de la contaminación ambiental? Revista de Ciencias Ambientales, 55(2). https://www.scielo.sa.cr/pdf/rca/v55n2/2215-3896-rca-55-02-1.pdf
García Alvarado, R., Herrera Ojeda, R., Muñoz Viveros, C., & Wandersleben, G. (2016). Desempeño ambiental de recintos habitacionales. Comparación de simulaciones, monitorización y percepción de residentes en seis viviendas de Concepción, Chile. Revista Tecnura, 20(47). https://doi.org/10.14483/udistrital.jour.tecnura.2016.1.a06
Gil-Baez, M., Lizana, J., Becerra Villanueva, J. A., Molina-Huelva, M., Serrano-Jimenez, A., & Chacartegui, R. (2021). Natural ventilation in classrooms for healthy schools in the COVID era in Mediterranean climate. Building and Environment, 206. https://doi.org/10.1016/j.buildenv.2021.108345
Li, C., & Tang, H. (2021). Study on ventilation rates and assessment of infection risks of COVID-19 in an outpatient building. Journal of Building Engineering, 42. https://doi.org/10.1016/j.jobe.2021.103090
Massacane, A., Vorobioff, J., Pierpauli, K., Boggio, N. G., Reich, S., Rinaldi, C. A., Boselli, A., amagna, A., Azcárate, M. L., Codnia, J., & Manzano, F. (2010). Increasing electronic nose recognition ability by sample laser irradiation. Sensors and Actuators, B: Chemical, 146(2). https://doi.org/10.1016/j.snb.2009.12.033
Ostro, B. D., Broadwin, R., & Lipsett, M. J. (2000). Coarse and fine particles and daily mortality in the Coachella Valley, California: A follow-up study. Journal of Exposure Analysis and Environmental Epidemiology, 10(5). https://doi.org/10.1038/sj.jea.7500094
Persily, A., & de Jonge, L. (2017). Carbon dioxide generation rates for building occupants. Indoor Air, 27(5). https://doi.org/10.1111/ina.12383
Quesada Carvajal, L. V., Pino Gomez, M., & Elizondo Hernández, R. (2018). Estimación emisiones de compuestos orgánicos volátiles, plantel de distribución de combustibles Recope, el Alto de Ochomogo, Cartago, Costa Rica. Tecnura, 22(55). https://doi.org/10.14483/22487638.12543
Rodríguez, D., Bonaparte, J., Boggio, N., & Fasciszewski, A. (2019). Desarrollo y fabricación de un microsensor de gas de baja potencia para la detección de amoniaco a bajas concentraciones. Tecnura, 23(61). https://doi.org/10.14483/22487638.15353
Sanchez Quintero, T., Gómez Santamaría, C., & Hincapié Reyes, R. C. (2021). Localización de múltiples fuentes basada en información de dirección de llegada mediante el uso de la teoría de sensado comprimido de la posición basado en información de dirección de llegada aplicando sensado comprimido a la matriz de covarianza. Tecnura, 25(67). https://doi.org/10.14483/22487638.16302
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012). Is CO2 an indoor pollutant? direct effects of low-to-moderate CO2 concentrations on human decisionmaking performance. Environmental Health Perspectives, 120(12). https://doi.org/10.1289/ehp.1104789
Shen, Chen. (2014). An Investigation of a Low-cost CO2 Indoor Air Quality Monitor. https://www.researchgate.net/publication/273770363_An_Investigation_of_a_Low-cost_CO2_Indoor_Air_Quality_Monitor.
Schibuola, L., & Tambani, C. (2021). High energy efficiency ventilation to limit COVID-19 contagion in school environments. Energy and Buildings, 240. https://doi.org/10.1016/j.enbuild.2021.110882
Tusman, G., Campos, M., & Gogniat, E. (2020). COVID-19: how to transform a noninvasive ventilation device in a critical care ventilator. Revista Espanola de Anestesiologia y Reanimacion, 67(7). https://doi.org/10.1016/j.redar.2020.05.002
Vorobioff, J., Boggio, N., Gutierrez, M., Checozzi, F., & Rinaldi, C. (2020). Design of drones for monitoring of volcanic areas. Tecnura, 24(66). https://doi.org/10.14483/22487638.16800
Zivelonghi, A., & Lai, M. (2021). Mitigating aerosol infection risk in school buildings: the role of natural ventilation, volume, occupancy and CO2 monitoring. Building and Environment, 204. https://doi.org/10.1016/j.buildenv.2021.108139
Cómo citar
APA
ACM
ACS
ABNT
Chicago
Harvard
IEEE
MLA
Turabian
Vancouver
Descargar cita
Licencia
Derechos de autor 2024 Juan Vorobioff, Norberto Gabriel Boggio, Federico Ricardo Checozzi, Tamara Pinto Garrón, Carlos Rinaldi
Esta obra está bajo una licencia internacional Creative Commons Atribución-CompartirIgual 4.0.
Esta licencia permite a otros remezclar, adaptar y desarrollar su trabajo incluso con fines comerciales, siempre que le den crédito y concedan licencias para sus nuevas creaciones bajo los mismos términos. Esta licencia a menudo se compara con las licencias de software libre y de código abierto “copyleft”. Todos los trabajos nuevos basados en el tuyo tendrán la misma licencia, por lo que cualquier derivado también permitirá el uso comercial. Esta es la licencia utilizada por Wikipedia y se recomienda para materiales que se beneficiarían al incorporar contenido de Wikipedia y proyectos con licencias similares.