Publicado:
2021-06-28Edição:
v. 18 n. 1 (2021)Seção:
Investigación y DesarrolloResultados generados por haces de fotones en un maniquí simulado en Geant4
Results generated by beams of photons on a simulated mannequin in Geant4
Palavras-chave:
Dosis, Energía depositada, Geant4, Maniquí, RX (es).Palavras-chave:
Dose, Deposited energy, Geant4, Phantom, RX (en).Downloads
Resumo (es)
This paper aims to validate the software Geant4 radiotherapy applications, generating a phantom with densities approximated to those of the CIRS 002LFC IMRT Thorax Phantom model, which is used in the characterization and calibration of X-ray beams (RX) in linear accelerators (LINAC), this is incident photon you beam RX 6 MeV generated at a distance of 100 cm from the detector set to Geant4 which is located at the isocenter of the manikin. The detector captures the energy deposited at the indicated depth as well as the dose. As a result, it is possible to build the PDD for a simulated tank and the dose in the isocenter is calculated with a number of events of the order of 106, thus demonstrating the viability of the code to generate the necessary data for more robust simulations.
Referências
S. Andreo, “Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water”, Iaea Trs, Austria, 2000.
Sociedad Española de Oncología Médica SEOM, “Página inicial”, 2020. [En línea]. Disponible: https://seom.org/
Instituto Nacional de Salud, Observatorio Nacional de Salud, “Primer Informe ONS, aspectos relacionados con la frecuencia de uso de los servicios de salud, mortalidad y discapacidad en Colombia”, Imprenta Nacional de Colombia, Bogotá D.C., 2011.
F. Salvat, J. M. Fernández-Varea, J. Sempau, “PENELOPE-2006: A code system for Monte Carlo simulation of electron and photon transport”, Barcelona: OECD, 2006.
Computerized Imaging Reference Systems CIRS, “Manual Tissue Simulation & Phantom Technology”, Norfolk, Virginia, 2017.
A. Brosed, “Fundamentos de física médica”, vol. 1, Madrid: ADI, 2011.
H. Andreo, “Fundamentals of ionizing radiation dosimetry”, 2017.
M. Pérez, G. A. Cavanzo Nisso, F. Villavisán Buitrago, "Sistema embebido de detección de movimiento mediante visión artificial", Vis. Electron., vol. 12, no. 1, pp. 97–101, 2018. https://doi.org/10.14483/22484728.15087
S. Agostinelli, “Simulation toolkit, Nuclear instruments and methods in physics”, vol. 506, no. 3, pp. 250-303, 2003. http://dx.doi.org/10.1016/S0168-9002(03)01368-8
Como Citar
IEEE
ACM
ACS
APA
ABNT
Chicago
Harvard
MLA
Turabian
Vancouver
Baixar Citação
Visitas
Downloads
Licença
Copyright (c) 2021 Revista Vínculos

Este trabalho está licenciado sob uma licença Creative Commons Attribution-NonCommercial 4.0 International License.
Este obra está sob uma licença Creative Commons Atribuição 4.0